Pressure Transmitter with Wireless Data Trans
Model Number/Name | UMO Wtrans p |
Automation Grade | Automatic |
Input Pressure | -1 to 600 Barg |
Fluid Connection Type | 1/2" BSP |
Radio frequency | 868.4 MHz |
Relative Pressure | 0 to 250 mbar - 0 to 600 bar |
Absolute Pressure | 0 to 600 mbar - 0 to 25 bar |
JUMO Wtrans p - Pressure Transmitter with Wireless Data Transmission Features
Feature: for stationary and mobile pressure measurement
- 0 to 250 mbar up to 0 to 600 bar relative/absolute
- Radio frequency 868.4 MHz
- Range in free field up to 300 m
- Battery status monitoring
- Optionally available in combination: analog output, serial interface, and relay contact in associated DIN rail receiver
- Configurable with easy-to-use PC setup program
- Configurable transmission interval (0.5 to 3600 s)
- Configurable transmitter detection
- Customer-specific linearization (value pairs in tabular form or polynomial of the fourth order)
- OnlineChart of the measured values
Customer benefits
- Process reliability
The sensors have a high level of overload protection and long-term stability. The full final inspection in the fully-automated measuring and calibration facility ensures that each pressure transmitter is of high quality.
- Time-saving, simple, and versatile
The pressure transmitter is configured by connecting a laptop with the easy-to-use setup program installed (connection with standard mini USB cable). Once the process parameters are determined they can be conveniently and reliably transferred to other devices. Regardless of whether the device is used on stationary plants, in locations that are difficult to access, mobile systems, or even on moving and rotating components, the JUMO Wtrans p reduces mounting and installation effort in the concept phase or retrofitting. It also negates the need for a cable, which is especially important when cable laying is not possible or is technically complicated.
- Always application-oriented
Special applications can be integrated with up to 40 pairs of values by using customer-specific linearization. In addition: a polynomial of the fourth order can be entered or determined based on the added tabular values. In addition, a measured value diagram, referred to as OnlineChart, can be included in the setup. This graphic monitoring for analysis and documentation of the measured values supports your startup processes.
Applications
- Replacement for cables when cable laying is technically challenging or too costly
- For spatial mobility: for use with moving, rotating, traveling, and non-fixed plant components
- For unrestricted flexibility (e.g. for temporary measurements) whereby time-intensive mounting and installation is not required
- For hygienic processes