Products

pattern

FUJI FCX-AIII Series Pressure Transmitters and Differential Pressure (Flow) Transmitters

BrandFUJI Electric
Electrical ConnectionM20 x 1.5
MountingIntegral with manifold or Remote (2" pipe)
Accuracy (%)0.4 FS
Turn Down Ratio1 10
Measuring Ranges130 to 50000 KPa
ConditionNew
Wetted PartSS316, Monel, Hatelloy C-276
Connectivity TypeLoop powered
Power Supply24VDC
Filling LiquidSilicone Oil
Display TypeIntegral LCD
Output Signal (mA)4-20mA HART
Output Signal4 - 20mA HART
Mounting TypeIntegral or Remote
Media Typeliquid, Gas, Steam
TypeSmart Transmitter
Ip RatingIP 67
Load Resistance (ohm)600
Material GradeSS316, Monel, Hastelloy C-276
Process Connection1/4NPT or Flanged
ProtectionATEX Flame proof
Input Pressure130 to 50000 Kpa
Fluid Connection Type1/4" NPT or Flange

FCX-AIII series transmitters are electronic transmitters which use electrostatic capacitance sensors. They feature compact design, high accuracy, and long-term stability, and offer a variety of diaphragm materials. You can select from: type L housing suited to a vertical pipe, type T housing to horizontal pipe, and direct mount type.

High accuracy

Up to ±0.04% (Option) / ±0.065% (Standard*)

Diaphragm materials

  • 316L SS
  • Hastelloy-C
  • Monel
  • Tantalum
  • 316L SS Gold-plated
  • Gold & ceramic coating

Maximum span (kPa) [URL]

130 to 50000

Process connection

1/4"NPT or Flange connection

Common specifications

  • Elevation / Suppression: -100 to +100%URL
  • Span setting range: 1 to 1/100URL
  • Setting interval: 60ms
  • Temperature range:
  • Sensor unit: -40 to +120°C
  • (version for higher temperature available)
  • Electronics: -40 to 85°C
  • Power supply voltage: 10.5–45V DC
  • Output signal / Allowable load resistance:
  • 4–20mA DC/600Ω or less (When 24V DC is applied)
  • Communication protocol: Fuji protocol or HART protocol
  • Damping time constant: configurable between 0–32 s
  • Zero/span adjustment: by adjustment screws, by optional field
  • configurator, or by HHC.
  • Electric cable inlet: G1/2, 1/2-14 NPT, pg13.5 or M20×1.5
  • Options: Analog indicator, digital indicator, cleaning for oxygen service, cleaning for chlorine service, stainless housing, stainless tag plate, field configurator